The
SART Tester is designed for check of any SART in accordance with the
requirements of SOLAS - 74/88, and the Russian Marine Register rules
M.628-2.
The International Marine Organisation requires
that all GMDSS radio equipment is maintained to ensure it meets the
appropriate perfomance requirements. In the event of test failure, ships
may be detained in Port The SART Tester provides measurement
of the carrier frequency, duration and power of the response. The device
has small dimention and ican be easily placed in hand.
Now with
the help of SART Tester it is possible to test the SART to ensure it
meets the appropriate perfomance requirements. The SART Tester is
portatible and easy in use. It is far more effective than the primitive
self-test function offered by any SART. The Test results shown on LCD
Display or printered make easy the futher analysis of the SART
efficiency.
NATO Serial Number: 6625-12-379-2933
The device allows to: - measure the carrier frecuency of response in range of 9140...9560 MHz; - measure the duration of response in range of 50...150 microseconds; - indicate the power level in range of 300...950 mW; - calculate the quantity of sweep frecuency points in the response; - control the power supply voltage with displaying on LCD; - print the full protocol of the device test Calculation of SART parameters are made thought the broadcast. The test duration with displaying on LCD - not more then 2 Minutes.
Environment: The
device is designed for operation in the inside shielded rooms of the
vessel with the temperature +5 С...+55 С and relative humidity of air
95%.
The complete set of SART tester includes:
- Main unit - Connection cables - ААА type 6V batteries (4 units) - Software - 6-9V power supply unit - English manual
Features: - The device provides measurement of SART parameters in AUTO mode - The device provides control and displaying on LCD of the power supply voltage up to ±5% - The time of the operation without recharge of accumulator is not less 7 hours - Current consumption of the device power supplied by accumulator: in standby mode - 85 mA, in measurement mode - 270 mA; - Current consumption of the device power supplied through supply unit: in standby mode - 95 mA, in measurement mode - 300 mA; - The device provides the recharge of accumulator through the power suplly unit. Max time of recharge - not more then 16 hours - The device allows to save in memory 10 blocks of measured parameters.
|